The HAG series hot air generators are offered in vertical or horizontal designs, either as standard models or tailor-made models to match customer's specifications and applications. Designed in DIRECT and INDIRECT heating types, these systems are practically free from any maintenance and are highly efficient.
Direct systems find their applications in high temperature drying, whereas the Indirect systems are used where pure air is required for drying. The design is compact & hence space saving. Units are designed for continuous round the clock operation.
The gas fired hot air generator we manufacture is ranging from 50,000 kcal/hr to 15, 00,000 kcal/hr. The payback periods will be 2 to 10 months against oil / gas fired or electrical hot air generators.
Salient features of the RG series hot air generators are:
Very high thermal efficiency up to 80%
Less maintenance due to minimum usage of refractory in furnace
Vertical & Horizontal design
Easy access for maintenance
Less pollution by using dust collectors.
Urable construction
Easy operation and minimal maintenance
High level of safety in operation, thus greater reliability
Optional recirculation system to improve overall thermal efficiency
Fully automatic burner control and temperature control
Units are available from capacities of 20,000 Kcal/hr to 30,00,000
DETAILS
UITS
HAG 10
HAG 20
HAG 30
HAG 40
HAG 60
Rated hit output
kcal/hr
100000
200000
300000
400000
600000
Maximum Air Temp.
C°
200
200
200
200
200
Outlet Air Pressure
mm of Water G.
100
100
100
100
100
Approx Hot Air Available at 200°C
kg/hr.
2290
4580
6870
9160
13740
m³/hr
1910
3815
5725
7585
11450
Overall Thermal Efficiency On GCV
%
86± 1
Fuel Oil Consumption for rated out put
LDO (GCV 10200)kcal/kg
kg / hr
10.70
21.5
32.2
45.6
64.3
F.O. (GCV 10200 kcal/kg
kg/hr
-
23.8
39.8
48
67.6
BURNER CONTROL <------------------- ON-OFF -------------------> HIGH/LOW Electric Supply 415V±5% 50 Hz 3ph 4 Wire